Prof. Alberto Herrera-Gomez

0 Spicer points

0 Followers

Posts

Information

  • from W powder
    Read more

    Files :

    • You must be logged-in to download data

    Equipment and analysis software:

    • Software used: AAnalyzer

    AAnalyzer_28_image_14.jpg
  • Used Voigt. Works well, no need for asymmetric lines. The energies are off by about - 7 eV
    Read more

    Files :

    • You must be logged-in to download data

    Information about the sample:

    • Shape: Flat surface

    • Sample material: KMnO4

    • Elements: K, Mn, O

    Equipment and analysis software:

    • Software used: AAnalyzer

    AAnalyzer_19_image_14.jpg
  • The peaks are symmetric, no need for DL or CR. Energies off by about -7 eV
    Read more

    Files :

    • You must be logged-in to download data

    AAnalyzer_25_image_14.jpg
  • Used CR type II plus a Gaussian wide peak
    Read more

    Files :

    • You must be logged-in to download data

    Information about the sample:

    • Shape: Flat surface

    • Sample material: KMnO4

    • Elements: K, Mn, O

    Equipment and analysis software:

    • Software used: AAnalyzer

    AAnalyzer_16_image_14.jpg
  • Used CR type II plus an small Gaussian peak. CR type III fits well without the need of the second peak, but difE2 doesn't make sense (too large).
    Read more

    Files :

    • You must be logged-in to download data

    Information about the sample:

    • Shape: Flat surface

    • Sample material: MnO2

    • Elements: Mn, O

    • Sample composition: MnO2

    Equipment and analysis software:

    • Software used: AAnalyzer

    AAnalyzer_20_image_14.jpg
  • main peak required CR III
    Read more

    Files :

    • You must be logged-in to download data

    Information about the sample:

    • Sample material:

    • Elements:

    • Sample composition:

    Data acquisition parameters:

    • Pass energy:

    • Take-off angle:

    Equipment and analysis software:

    • Brand:

    • Model:

    • Spectrometer mode:

    • Software used: AAnalyzer

    AAnalyzer_34_image_14.jpg
  • with Voigt was enough
    Read more

    Files :

    • You must be logged-in to download data

    Information about the sample:

    • Sample material:

    • Elements:

    • Sample composition:

    Data acquisition parameters:

    • Pass energy:

    • Take-off angle:

    Equipment and analysis software:

    • Brand:

    • Model:

    • Spectrometer mode:

    • Software used: AAnalyzer

    AAnalyzer_33_image_14.jpg
  • with Voigt was enough
    Read more

    Files :

    • You must be logged-in to download data

    Information about the sample:

    • Sample material:

    • Elements:

    • Sample composition:

    Data acquisition parameters:

    • Pass energy:

    • Take-off angle:

    Equipment and analysis software:

    • Brand:

    • Model:

    • Spectrometer mode:

    • Software used: AAnalyzer

    AAnalyzer_32_image_14.jpg
  • used CR type II correlating the Gaussian widths
    Read more

    Files :

    • You must be logged-in to download data

    Equipment and analysis software:

    • Software used: AAnalyzer

    AAnalyzer_29_image_14.jpg
  • Used CR type II. Great fit.
    Read more

    Files :

    • You must be logged-in to download data

    AAnalyzer_12_image_14.jpg
  • too many Voigts
    Read more

    Files :

    • You must be logged-in to download data

    Equipment and analysis software:

    • Software used: AAnalyzer

    AAnalyzer_26_image_14.jpg